If the beacon just switched from Low Speed into High Speed mode and High Speed mode defines a minimum duration of 10 seconds, the beacon will have to stay in High Speed mode for at least the next 10 seconds.
If the beacon just switched from Low Speed into High Speed mode and High Speed mode defines a minimum duration of 0 seconds, the beacon can switch back to Low Speed mode at any time.

Maximum Duration

Defines the maximum duration to remain in the current mode after a mode switch.

...

After the beacon switches between modes, different data filters might apply. In order to let the filtered values settle after a mode change you can specify this parameter. If specified, feature calculation and sampling will only start after a mode change after this amount of raw acceleration samples have been skipped.

Output Fields

The checkboxes in this section allows you to specify the features that the beacon shall calculate and advertise. Multiple output fields can be selected at once.

...